8
WITHOUT THE CORRECT AMOUNT OF METHYL ALCOHOL SOLUTION
IN THE BOOSTER TANK. EMPTY THE BOOSTER TANK EVERY 12-16
HOURS OF RUNNING TIME. WASH THE TANK IN HOT WATER AND
DRY BEFORE USING.
4. Press on the proper size tip to the end of the torch. (See tip size
chart on page 11)
5. Turn the machine on by pushing the on/off switch to ON position.
Turn the round knob so that it corresponds to the setting in the tip
chart. In 30 seconds to 1 minute, you can feel gas flowing out of the
tip of the torch and hear gas bubbling in the booster tank. When this
occurs, light the torch. If more gas is required, turn the knob to a
higher position.
a. Conversely, if less gas is required, turn the knob to a lower
position. Use the lower position for tips with smaller orifice.
CAUTION: NEVER light the torch until you can feel gas coming from
the tip of the torch. Never change the tips without first putting out
the flame. The machine can remain on when removing tips.
6. To turn off the machine first put out the flame. To put out the flame
push in the back of the torch. When the flame is out, shut off the
machine. Always leave the tip open to allow gas to escape.
CAUTION: ALWAYS remove the booster tank before opening the
water tank cover. This is to prevent methyl alcohol solution from
being sucked into the water tank and contaminating it.