Loading...
ST7735R
V0.2 27 2009-08-05
9.2 8080-series MCU parallel interface (P68 = ‘0’)
The MCU can use one of following interfaces: 11-lines with 8-data parallel interface, 12-lines with 9-data parallel interface,
19-line with 16-data parallel interface or 21-lines with 18-data parallel interface. The chip-select CSX (active low)
enables/disables the parallel interface. RESX (active low) is an external reset signal. WRX is the parallel data write enable,
RDX is the parallel data read enable and D[17:0] is parallel data bus.
The LCD driver reads the data at the rising edge of WRX signal. The D/CX is the data/command flag. When D/CX=’1’,
D[17:0] bits is either display data or command parameter. When D/C=’0’, D[17:0] bits is command. The interface functions
of 8080-series parallel interface are given in following table.
IM2
IM1
IM0
Interface D/CX
RDX
WRX
Read back selection
0 1 Write 8-bit command (D7 to D0)
1 1 Write 8-bit display data or 8-bit parameter (D7 to D0)
1 1 Read 8-bit display data (D7 to D0)
1 0 0
8-bit
parallel
1 1 Read 8-bit parameter or status (D7 to D0)
0 1 Write 8-bit command (D7 to D0)
1 1 Write 16-bit display data or 8-bit parameter (D15 to D0)
1 1 Read 16-bit display data (D15 to D0)
1 0 1
16-bit
parallel
1 1 Read 8-bit parameter or status (D7 to D0)
0 1 Write 8-bit command (D7 to D0)
1 1 Write 9-bit display data or 8-bit parameter (D8 to D0)
1 1 Read 9-bit display data (D8 to D0)
1 1 0
9-bit
parallel
1 1 Read 8-bit parameter or status (D7 to D0)
0 1 Write 8-bit command (D7 to D0)
1 1 Write 18-bit display data or 8-bit parameter (D17 to D0)
1 1 Read 18-bit display data (D17 to D0)
1 1 1
18-bit
parallel
1 1 Read 8-bit parameter or status (D7 to D0)
Table 9.2.1 the function of 8080-series parallel interface
Note: applied for command code: DAh, DBh, DCh, 04h, 09h, 0Ah, 0Bh, 0Ch, 0Dh, 0Eh, 0Fh