ST ST7735R - 10.1.16 GAMSET (26 h): Gamma Set

ST ST7735R
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ST7735R
V0.2 99 2009-08-05
10.1.16 GAMSET (26h): Gamma Set
26H GAMSET (Gamma Set)
Inst / Para
D/CX
WRX
RDX
D17-8
D7 D6 D5 D4 D3 D2 D1 D0 HEX
GAMSET
0 1 - 0 0 1 0 0 1 1 0 (26h)
Parameter
1 1 - - - - - GC3
GC2
GC1
GC0
Description
-This command is used to select the desired Gamma curve for the current display. A maximum of 4 curves can be
selected. The curve is selected by setting the appropriate bit in the parameter as described in the Table.
GC [7:0] Parameter Curve Selected
GS=1 GS=0
01h GC0 Gamma Curve 1 (G2.2) Gamma Curve 1 (G1.0)
02h GC1 Gamma Curve 2 (G1.8) Gamma Curve 2 (G2.5)
04h GC2 Gamma Curve 3 (G2.5) Gamma Curve 3 (G2.2)
08h GC3 Gamma Curve 4 (G1.0) Gamma Curve 4 (G1.8)
Note: All other values are undefined.
Default
Status Default Value
Power On Sequence 01h
S/W Reset 01h
H/W Reset 01h