ST315 Temperature Programmer
See separate handbook for Installation Instructions
© Copyright 2004, 2005 Stafford Instruments Ltd.
Question and Answer IconNeed help?

Do you have a question about the Stafford Instruments ST315 and is the answer not in the manual?

Summary

Error Messages

Error 1

Kiln temperature not increasing as required after 1 hour on full power.

Error 2

Thermocouple or thermocouple wiring open circuit.

Error 3

Thermocouple reversed, indicated by negative temperature readings.

Error 4

Kiln temperature too high after 30 minutes on zero power.

Error 5

Kiln temperature overshoot, exceeding desired temperature by at least 10°C.

Error 6

Maximum firing time exceeded, surpassing an installer-selectable limit.

Programming

Stafford Instruments ST315 Specifications

General IconGeneral
Temperature Range-50 to 400°C
Display3½ digit LED
Control ModePID
Power Supply110/240Vac
Accuracy0.25%
MountingPanel mount
Sensor TypeThermocouple
OutputRelay
Input TypeThermocouple
Control OutputRelay