Stagnoli E24 - Monitoring, Diagnostics, and Specifications; Interpreting Statistics and Diagnostic Screens; Technical Specifications

Default Icon
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30
GB
transmitter
in
the memory.
If
the transmitter
is
not found
in
the memory, the
display
will show
----.
•third
and
fourth screens:
show
the hexadecimal
code of
the
transmitter.
Statistics
screens
The
control
board has
four statistics screens that
are viewed by
keeping
the key
ENTER
pressed
once
the
display is
positioned
on
the main
menu:
•first screen:
E101,
where
E2
indicates the
motor Hermes
at 24V and
01
the
sof-
tware
version.
•second
and
third screens:
0000 0000
indicates the number
of
complete
mano-
euvres
undertaken.
•fourth screen: indicates the stroke
in
the
memory.
Diagnostics
screens
The control
board can
recognise problems
or
alarms that
can occur in
the
system,
therefore
it can signal
some messages
on
the main
display to allow
the
problem
to be identified:
•
1
rf
=
activation
of
the
START
command
on
the first
radio
frequency
channel.
•
2
rf
=
activation
of
the
START
command
on
the pedestrian
channel.
•
phO
=
activation
of
photocells input
in
closing
on
the terminal
board.
•
phoA
=
activation
of
photocells input
in closing and in
opening
on the terminal
board.
•
bar
= activation
of
the safety
rib.
•
sto
=
stop
impulse.
•
enc1
=
operation
of
the sensor
with
encoder
on
the first
motor.
•
enc2
=
operation
of
the sensor
with
encoder
on
the second
motor.
•
ope
=
activation
of
the opening command (with
oc=1
).
•
clo
=
activation
of
the closing command (with
oc=1
).
•
ped
=
activation
of
the pedestrian entry
command.
•
am1
=
activation
of
the anti-crushing sensor
on
motor
1.
•
am2
=
activation
of
the anti-crushing sensor
on
motor
2.
Technical
specifications
•Automation feed:
230V
-
50/60Hz.
•Primary transformer protection fuse:
T1,25A/230
V.
•Accessory
output protection fuse
24V: F2,5A.
•Integrated receiver
(433Mhz):
maximum
capacity 76 radio codes.
•Operating temperature:
-20° +55°
•Maximum rated
power of
motors:
70W+70W
•Flasher output maximum power:
25W
•Open
gate
detector output maximum
power (SCA):
5W
•Electronic anti-crushing
device:
amperometric
with encoder