Do you have a question about the Stan-Tech SDN11RH and is the answer not in the manual?
Problem: Trigger valve housing leaks air. Cause: O-ring cut or cracked. Correction: Replace O-ring.
Problem: Trigger valve stem leaks air. Cause: O-ring/seals cut or cracked. Correction: Replace trigger valve assembly.
Problem: Frame/nose leaks air. Cause: O-ring or Gasket is cut or cracked. Correction: Replace O-ring or gasket.
Problem: Frame/cap leaks air. Cause: Damaged gasket or seal. Correction: Replace gasket or seal.
Problem: Tool failure to cycle. Cause: Air supply restriction. Correction: Check air supply equipment.
Problem: Lack of power or slow cycling. Cause: Tool dry, lack of lubrication. Correction: Use Approved Air Tool Lubricant.
Problem: Skipping fasteners or intermittent feed. Cause: Worn bumper. Correction: Replace bumper.