16
77-121
P
1
D
2
1
2
P
1
D
1
D
1
2
D
1
2
2. Rotate laser unit to other corner or
reference point.
3. Measure the vertical distances between
P
1
and the horizontal beam from the 2nd
location.
4. Calculate the maximum allowed offset
distance and compare to D
2
. If D
2
is
not less than or equal to the calculated
maximum offset distance the unit must be
returned to your Stanley Distributor.
Example: D
1
= 5 m, D
2
= 1 mm
0,3 x 5 m = 1,5 mm (maximum allowed offset distance)
1 mm ≤ 1,5 mm (TRUE, unit is within calibration)
mm
m
Compare:
D
2
Max
Maximum Offset Distance:
Max
in
ft
= 0,0036 x D
1
ft
mm
m
= 0,3 x D
1