Reader Tamper
If the reader is pulled away from the wall, the tamper plug remains attached to the wall and
a reader tamper condition is generated.
The voltage on the Tamper line is normally low. If reader tamper is detected, the voltage on
the Tamper line becomes high and the reader sounds 3 long beeps every 5 seconds for two
minutes, then stops.
To clear a reader tamper condition, reattach the reader to the wall.
Usage
LEDs
Red / GreenGreenRed
Access deniedAccess permittedDefault
Sounder
•
The reader sounds 4 rapid beeps when it is powered up or restarted.
•
If specified, the reader beeps once when a token is presented.
Cable Lengths
PAC door controllers only
Distance from Reader to ControllerCable Gauge
AC 202 / 512AC 2100 / 2200
230′ / 70m *750′ / 250m7/0.2 0.34mm² 22AWG
230′ / 70m *1500′ / 500m16/0.2 0.5mm² 20AWG
230′ / 70m *3000′ / 1000m32/0.2 1.0mm² 18AWG
11
English