IMPORTANT POINTS TO REMEMBER
When pulling the starter rope, do not use the full extent of the 
rope as this can cause the rope to break. Do not let starter rope 
snap back . Hold the handle and let the rope rewind slowly.
For cold weather starting, start the unit at FULL CHOKE, allow 
the engine to warm up before squeezing the throttle trigger.
Note: Do not attempt to cut material with the choke/fast idle 
lever in the FULL CHOKE position.
To Stop The Engine (Pic. 12)
Move the ON/STOP switch to the OFF position.
Warning: DO NOT put the chainsaw on the ground when the 
chain is still moving.
Always engage the chain brake when it is not in use.
Starting a Cold Engine (Or Warm Engine After Running 
Out Of Fuel)
Note: In the following steps, when the choke lever is pulled out 
to the full extent, the correct throttle setting for starting is set 
automatically.
1.   Move the ON/STOP switch to the RUN position (Pic. 12).
RUN/ON  -  I depressed 
OFF  -  0 depressed
2.   Pull choke lever out to the full extent (to the FULL CHOKE 
position) (Pic. 13)
3.   Slowly press primer bulb 7 times.
4.   Pull the starter rope sharply 5 times with your right hand. 
Then proceed to the next step.
Note: If the engine sounds as if it is trying to start before the 5th 
pull, stop pulling and immediately proceed to the next step.
5.   Push the choke lever in to the HALF CHOKE position.
6.   Pull the starter rope sharply you’re your right hand until the 
engine starts.
7.   Allow the engine to run for approximately 5  seconds. Push 
choke lever back to off position.
Starting a Warm Engine
1.   Move ON/STOP switch to the ON position.
2.   Then push the lever in to the HALF CHOKE position.
3.   Pull the starter rope sharply you’re your right hand until the 
engine starts.
4.   Push the choke lever back to off position.
Difficult Starting (Or Starting a Flooded Engine)
The engine may be flooded with too much fuel if it has not 
started after 10 pulls. Flooded engines can be cleared of excess 
fuel by pushing the choke lever in completely (to the OFF CHOKE 
position) and then following the warm engine starting procedure 
listed above. Ensure the ON/OFF switch is in the ON position. 
Starting could require pulling the starter rope handle many 
times depending on how badly the unit is flooded. If engine fails 
to start, refer to the TROUBLESHOOTING TABLE or seek help 
from an authorised service centre.
PIC. 12
PIC. 13
Run 
Position
Priming Bulb
Choke Lever
Pull fully out 
for full choke