EasyManua.ls Logo

Stanley SPL3 - Accuracy Check and Calibration; Up and Down Plumb Beam Accuracy

Stanley SPL3
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
STHT77342
unittoprojectthefrontlaserbeamtoanewlocation.
• Thelaserpointatthenewlocationwillbelevelwiththe
rstpoint.
• Positionthedesiredobjectuntilalignedwiththelaser
point.
Accuracy Check and
Calibration
NOTE:
• Thelasertoolsaresealedandcalibratedatthefactoryto
theaccuraciesspecied.
• Itisrecommendedtoperformacalibrationcheckpriorto
itsrstuseandthenperiodicallyduringfutureuse.
• Thelasertoolshouldbecheckedregularlytoensureits
accuracies,especiallyforpreciselayouts.
• Whenperformingtheaccuracychecks,usethelargest
area/distancepossible,closesttotheoperatingdistance.
Thegreaterthearea/distance,theeasiertomeasurethe
accuracyofthelaser.
• The lock must be in the unlocked position to allow
the laser tool to self-level before checking the
accuracy.
Up and Down Plumb Beam
Accuracy
(See figure
M
)
•
M
1
PlacelaserunitasshownwithlaserON.Measure
distancesD
1
andD
2
.MarkpointsP
1
andP
2
.
•
M
2
Rotatelaserunit180°keepingsamedistancesforD
1
andD
2
.AligndownwardlaserbeamwithpointP
2
.Mark
pointP
3
.
•
M
3
MeasuredistanceD
3
betweenpointsP
3
andP
1
.
• CalculatethemaximumoffsetdistanceandcomparetoD
3
.
• If D
3
is not less than or equal to the calculated
maximum offset distance the tool must be returned to
your Stanley Distributor for calibration.
Maximum Offset Distance (SPL3):
=(D
1
mx0,6
mm
m
)+(D
2
mx1,2
mm
m
)
Maximum
=(D
1
ftx0,0072
in
ft
)+(D
2
ftx0,0144
in
ft
)
Compare : (See figure
M
3
)
D
3
≤Maximum
Example :
• D
1
=3m,D
2
=1m,D
3
=1,5mm
• (3mx0,6
mm
m
)+(1mx1,2
mm
m
)=3,0mm(maximum
offset distance)
• 1,5mm≤3,0mm(TRUE, tool is within calibration)