© 2015, Pinnacle Products International, Inc. 
668 Stony Hill Road #302 Yardley, PA 19067
RISK OF ELECTRIC SHOCK! DISCONNECT FROM POWER BEFORE MAINTENANCE.
WARNING
Plug Replacement
NOTE: This section only applies to heaters sold or used in Great Britain.
This appliance is supplied with a BS1363 3 pin 
plug tted with a fuse. Should the fuse require 
replacement, it must be replaced with a fuse 
with the proper amp rating. (see Technical 
Specications page 2) and approved to BS1362.
In the event the mains plug has to be removed/ 
replaced for any reason, please note: 
IMPORTANT: The wires in the mains lead are 
colored in accordance with the following code:
Blue – Neutral    Brown – Live 
Green/Yellow – Earth
As the colors of the wires in the mains lead of this 
appliance may not correspond with the colored 
markings identifying the terminals in your plug, 
proceed as follows:
The blue wire must be connected to the terminal 
marked with an N or colored black. The brown 
wire must be connected to the terminal marked 
with an L or colored red. The green/ yellow wire 
must be connected to the earthing terminal which 
is marked with an E or with the earth symbol.
NOTE: If a moulded plug is tted and has to 
be removed take great care in disposing of the 
plug and severed cable, it must be destroyed to 
prevent engaging into a socket.
Never connect live or neutral 
wires to the earth terminal of 
the plug.
GREEN / YELLOW
Earth
BROWN
Live
FUSE
5 Amps
CORD CLAMP
BLUE
Neutral
Plug Replacement Wiring Diagram
 Figure 3
8