NEVER LEAVE HEATER UNATTENDED WHILE CONNECTED TO A POWER SOURCE
6
© 2020, Obelis S.A Registered Address:
Bd. Général Wahis, 53, 1030 Brussels, Belgium
RISK OF ELECTRIC SHOCK! DISCONNECT FROM POWER BEFORE MAINTENANCE.
WARNING
PLUG REPLACEMENT
NOTE: This section only applies to heaters sold or used in Great Britain.
This appliance is supplied with a BS1363 3 pin
plug tted with a fuse. Should the fuse require
replacement, it must be replaced with a fuse with the
proper amp rating. (see Technical Specications page
2) and approved to BS1362.
In the event the mains plug has to be removed/
replaced for any reason, please note:
IMPORTANT: The wires in the mains lead are colored
in accordance with the following code:
Blue – Neutral Brown – Live
Green/Yellow – Earth
As the colors of the wires in the mains lead of this
appliance may not correspond with the colored
markings identifying the terminals in your plug,
proceed as follows:
The blue wire must be connected to the terminal
marked with an N or colored black. The brown wire
must be connected to the terminal marked with an
L or colored red. The green/ yellow wire must be
connected to the earthing terminal which is marked
with an E or with the earth symbol.
NOTE: If a moulded plug is tted and has to be
removed take great care in disposing of the plug
and severed cable, it must be destroyed to prevent
engaging into a socket.
Never connect live or neutral
wires to the earth terminal of
the plug.
WARNING
GREEN / YELLOW
Earth
BROWN
Live
FUSE
5 Amps
CORD CLAMP
BLUE
Neutral
Plug Replacement Wiring Diagram