  If the laser is NOT within its 4° compensation 
range:
• The rotary laser beam does NOT rotate.
• On the keypad,   FLASHES RED 
(Figure Ⓗ ①).
• The laser is not level and must be repositioned 
on a more level surface before use.
7.
  When you are nished using the laser tool in Self‑
leveling Mode, press   to turn the laser tool OFF.
Using Manual Mode
Manual Mode allows the laser tool to be positioned at 
any angle. When in manual mode, the laser tool is not 
guaranteed to be level.
1.
  Place the laser tool on a smooth, at, level surface.
2.
  Position the laser tool horizontally (Figure Ⓐ).
3.
 Move the Lock Switch to the right to select Manual 
Mode (Figure Ⓜ ②).
4.
 Press   to turn the laser tool ON.
5.
  Do not look into the laser beams as they turn on.
• The Rotary laser beam turns on and rotates 360° 
(Figure Ⓐ ①).
• The Plumb Up Dot laser beam turns on from the 
top of the laser tool (Figure Ⓐ ②).
6.
  On the keypad, make sure   (Figure Ⓗ ②) turns 
GREEN. If   is ashing RED, the battery level is 
low.
7.
  On the keypad, make sure   is solid RED 
(Figure Ⓗ ①)
8.
  Use the laser tool.
9.
  When you are nished using the laser tool in 
Manual mode, press   to turn the laser tool OFF.
Using the Vertical Position
Placing the laser in the Vertical Position repositions the 
laser by 90°. When positioned vertically, the laser does 
not compensate for an uneven surface. The laser is not 
guaranteed to be level.
1.
  Place the laser tool on a smooth, at, level surface.
2.
  Position the laser vertically (Figure Ⓑ).
3.
 Move the Lock Switch to the right to select Manual 
Mode (Figure Ⓜ ②).
4.
 Press   to turn the laser tool ON.
5.
  Do not look into the laser beams as they turn on.
• The Rotary laser beam turns on and rotates 360° 
(Figure Ⓐ ①).
• The Plumb Up Dot laser beam turns on from the 
top of the laser tool (Figure Ⓐ ②).
6.
  On the keypad, make sure   (Figure Ⓗ ②) turns 
GREEN. If   is ashing RED, the battery level is 
low.
7.
  On the keypad, make sure:
•   is solid RED (Figure Ⓗ ①).
•   turns ON (Figure Ⓑ ②).
8.
  Use the laser tool.
9.
  When you are nished using the laser tool in the 
Vertical Position, press   to turn the laser tool 
OFF.
Performing Accuracy Checks
NOTE:
•  The laser tool is sealed and calibrated at the factory 
to the Rotary Laser Specications listed in this 
manual.
•  It is recommended that you perform the accuracy 
checks before using the laser tool.
•  Be sure to allow the laser tool adequate time to 
Auto-Level (at least 5 seconds) prior to performing 
an accuracy check.