7.3  Safety valve (ref. 10)
The safety valve has been set for the highest permitted 
pressure of the pressure vessel. It is prohibited to adjust 
the  safety  valve. Actuate  the  safety  valve  from  time  to 
time to ensure that it works when required. Pull the ring 
with sufcient force until you can hear the compressed air 
being released (Fig. 11). Then release the ring again.
7.4  Storage
  Warning!  
Disconnect the plug from the socket, vent the 
appliance and tools connected to it and empty the 
condensate.
Switch off the compressor and make sure that it is 
secured in such a way that it cannot be started up 
again by any unauthorized person.
  Warning!  
Store the compressor only in a dry location which is 
not accessible to unauthorized persons.
Always store upright, never tilted!
8.  DISPOSAL AND RECYCLING
  Pursuant to Directive 2012/19/EU on 
waste electrical and electronic equipment (WEEE).
The symbol carrying a crossed-out refuse container 
depicted  on  any  equipment  or  the  relative  packaging 
means that, at the end of its useful life, said product must 
be disposed of separately from other waste. 
The  user  must  therefore  take  said  equipment  to  the 
centres specialising in differentiated refuse collection of 
electric  and  electronic  equipment  or  alternatively  return 
it to the reseller when purchasing a new similar piece of 
equipment. 
Thanks  to  differentiated  refuse  collection,  discarded 
equipment can be sent to be recycled, treated and disposed 
of  in  an  environmentally-friendly  manner;  this  helps 
avoiding possible negative effects on the environment 
and on health and promotes the re-employment and/or 
recycling of the equipment’s materials.
Any unauthorised disposal of the product by the user will 
result  in  the  application  of  the  nes  provided  for  by  the 
regulations in force.
9.  POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES
Fault Cause Remedy
The compressor stops and restarts 
automatically after a few minutes.
Tripping of the thermal cutout due to 
overheating of the motor.
Allow the compressor to cool down. 
Ventilate the work area.
After a few attempts to restart, the 
compressor stops.
Tripping of the thermal cutout due to 
overheating of the motor (removal 
of the plug with the compressor 
running, low power voltage).
Activate the I/O switch (On/Off). 
Ventilate the work area. Wait a few 
minutes. The compressor will restart 
independently.
The compressor does not stop and 
the safety valve is tripped.
Irregular compressor operation or 
pressure switch malfunction.
Remove the plug and contact the 
Service Center.
Any other type of operation must be carried out by authorized Service Centers, requesting original 
parts. Tampering with the machine may impair its safety and in any case make the warranty null 
and void.