8
2M-Z16009 Star-Max Electric Griddle
MATERIAL
DR.
DATE
FINISH
MODEL NO.
TITLE
PART NO.
TOLERANCES UNLESS OTHERWISE NOTED
FRACTIONS ±1/64 DECIMALS ±.005 ANGLES ±1°
REVISIONS
536TGD
SK1927
WIRING DIAGRAM 36" ELEC. GRIDDLE
TH
2-20-03
CK.
LTR DATE DESCRIPTION OF CHANGE DR
THIS DRAWING CONTAINS INFORMATION CONFIDENTIAL TO STAR MFG. INT'L. INC.
NO REPRODUCTION OR DISCLOSURE OF ITS CONTENTS IS PERMITTED.
STAR MANUFACTURING INTERNATIONAL INC.
#10 SUNNEN DRIVE, ST. LOUIS, MO. 63143, USA
NOMINAL AMPS PER LINE
208V-3 PHASE
9,012 WATTS
X
25.0
AWG #12
Y Z
240V-3PHASE
12,000 WATTS
X Y Z
AWG #10
28.925.025.0 28.9 28.9
240V SINGLE PHASE
12,000 WATTS
X-Y
50
AWG #6
208V SINGLE PHASE
9,012 WATTS
X-Y
43.3
AWG #6
A
4-5-13
ADDED SINGLE PHASE INFORMATION
MH
PILOT LIGHT
THERMOSTAT
1
3
2
2
1
HEATING ELEMENT
6
2
1
2
1
8
7
2
2
1
1
4
5
X
Y
Z
X
Y
5
7
3
4
8
6
THREE PHASE
SINGLE PHASE
NOTE:
1) FOR SUPPLY CONNECTIONS USE COPPER WIRE ONLY, SUITABLE FOR AT
LEAST 90°C (194°F). USE GAUGE SHOWN OR LARGER.
2) ALL INTERNAL WIRING IS #14 GA.
MATERIAL
DR.
DATE
FINISH
MODEL NO.
TITLE
PART NO.
TOLERANCES UNLESS OTHERWISE NOTED
FRACTIONS ±1/64 DECIMALS ±.005 ANGLES ±1°
REVISIONS
548TGD
SK1928
WIRING DIAGRAM 48" ELEC. GRIDDLE
TH
2-20-03
CK.
LTR DATE DESCRIPTION OF CHANGE DR
THIS DRAWING CONTAINS INFORMATION CONFIDENTIAL TO STAR MFG. INT'L. INC.
NO REPRODUCTION OR DISCLOSURE OF ITS CONTENTS IS PERMITTED.
STAR MANUFACTURING INTERNATIONAL INC.
#10 SUNNEN DRIVE, ST. LOUIS, MO. 63143, USA
THREE PHASE PARALLEL SUPPLY
208
12,016
X
38.2
AWG
#6
Y Z
240
16,000
X Y Z
#6
AWG
44.22538.2 44.2 29
#6
AWG AWG
#8 #6
AWG
#8
AWG
NOMINAL AMPS PER LINE
#10 #8
28.88
AWG
33.3
AWG
208 240
FOR SUPPLY USE
SINGLE PHASE DUAL SUPPLY
WIRE SIZE SHOWN OR LARGER
X-Y X-Y
80006,008
RATED WATTAGE
VOLTAGE
PHASE
#10
AWG
28.88
X-Y
6,008
#8
X-Y
AWG
33.3
8000
A
3/6/2012
CORRECTED SINGLE PHASE BALLOONS
FROM Z TO Y
JGL
1
SINGLE PHASE
CONNECTION
2 2
2
1
1
2
1
2 2
THERMOSTAT
11
2 2
1 1
PILOT
LIGHT
HEATING ELEMENT
6
3
5
4
FRAME
GROUND
3 PHASE
CONNECTION
5
3
6
4
X Y
Z
Y
X
6
SINGLE PHASE
CONNECTION
3
4
5
Y
X
FRAME
GROUND
YX
4
6
3 PHASE
CONNECTION
5
3
Z
NOTE:
1) FOR SUPPLY CONNECTIONS USE COPPER WIRE
ONLY, SUITABLE FOR AT LEAST 90°C (194°F).
USE WIRE GAUGE SHOWN OR LARGER.
2) ALL INTERNAL WIRING IS #14 GA.
A
A