26 - GB
13 Technical Data
IS/ISC - A(L) /
IS/ISC - AR(L) /
IS/ISC - ARD(L)
IS/ISC - A(L) /
IS/ISC - AR(L) /
IS/ISC - ARD(L)
IS M+H ISC M+H ISC Asbest
IS Asbest
Voltage V ~ 220–240 220–240 220–240 220–240 220–240
Frequency Hz 50/60 50/60 50/60 50/60 50/60
Rated power W 1200 1400 1200 1400 1000
Max. power W 1400 1600 1400 1600 1200
Air ow* m³/h/MG 220 230 -- -- --
Negative pressure* hPa/MG 248 259 -- -- --
Air ow m³/h/SE 140 150 140 150 140
Negative pressure** hPa/SE 225 236 225 236 225
Noise level dB (A) 69,5 70,0 69,5 70,0 69,5
L x W x H cm (50 l) 58,7 x 47 x 64
(25 l) 45,7 x 40 x 54
Weight kg 12,7 17,7
* at the fan, ** at the hose
Connection line on vacuum cleaners with plug socket: H05VV-F 3x1.5 / H07RN-F 3G 1.5
14 Tests and approvals
Electro-technical tests must be carried out in accordance with the accident prevention regulations (BGV A3) and in accordance with
DIN VDE 0701 Part 1 and Part 3. These tests are required in accordance with DIN VDE 0702 at regular intervals and after repair or modi
-
cation.
The vacuum cleaners are successfully tested in accordance with IEC/EN 60335–2–69.
NOTE
Old equipment contains valuable materials which are designed
for re-processing. The vacuum cleaners must not be thrown
away in the normal household waste, but should be disposed
of at a suitable proper collection system, e. g. via your communal
disposal location.