Thank you for buying this energy efficient water heater. We
appreciate your condence in our products.
You should thoroughly read this manual before installation and/
or operation of this water heater. Please pay particular attention
to the important safety and operating instructions as well as the
WARNINGS and CAUTIONS.
Instruction Manual
KEEP THIS MANUAL IN THE POCKET ON HEATER FOR FUTURE REFERENCE
WHENEVER MAINTENANCE ADJUSTMENT OR SERVICE IS REQUIRED.
ALL TECHNICAL AND WARRANTY QUESTIONS: SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS
PURCHASED. IF YOU ARE UNSUCCESSFUL, PLEASE WRITE TO THE COMPANY LISTED ON THE RATING PLATE ON THE WATER HEATER.
RESIDENTIAL GAS WATER HEATERS
For Your Safety
AN ODORANT IS ADDED TO THE GAS USED
BY THIS WATER HEATER.
GAS MODELS POWER VENT GS675YRVIT AND GS675HRVIT
WITH HOT SURFACE IGNITION
PRINTED 1010 197218-003
500 Tennessee Waltz Parkway,
Ashland City, TN 37015
www.statewaterheaters.com
Low Lead Content

Table of Contents

Questions and Answers

  • S
    Shawn MccarthyAug 15, 2025
    What to do if my State Water Heaters Water Heater has ignition failure?
    • M
      marthajenkinsAug 15, 2025
      If the gas control valve/thermostat has reached the maximum number of retries for ignition and is locked out, first ensure the flame sensor is making good contact with the burner flame and that the flame is steady. Also, verify that the gas supply and manifold pressures meet the requirements in the installation manual. Clean the flame sensor with fine steel wool if it's dirty. Inspect the igniter assembly plug and the socket on the gas control valve/thermostat for a secure connection. If the plug is worn or damaged, replace the igniter assembly. If the socket is worn or damaged, replace the gas control valve/thermostat. As a last resort, replace the igniter assembly.
  • A
    Alejandra MoralesAug 18, 2025
    What to do if the temperature sensor is open or shorted in my State Water Heaters Water Heater?
    • C
      Christy Bright DDSAug 18, 2025
      If the self-diagnostic check has detected the water temperature sensor is open or shorted, turn the power off for 10-20 seconds then on again to clear these error codes. If the error code persists, replace the gas control valve/thermostat.
  • W
    William MejiaAug 21, 2025
    How to troubleshoot an open igniter circuit in my State Water Heaters GS675HRVIT Water Heater?
    • A
      Amanda SaundersAug 22, 2025
      If the gas control valve/thermostat has detected an open igniter circuit, check the wiring to the hot surface igniter assembly; replace the igniter assembly if the wiring is damaged or worn. Check the resistance of the igniter at the igniter assembly plug—it should be between 11 and 18 ohms at room temperature (77° F at the plug end). Replace the igniter if it is open or shorted. Ensure the igniter assembly plug and the socket on the gas control valve/thermostat have a good connection. Replace the igniter assembly if the plug is worn or damaged. If the igniter assembly socket on the bottom of the control is worn or damaged, replace the gas control valve/thermostat.
  • R
    Rodney HarrisAug 26, 2025
    What does it mean when the black resistor wire is open or shorted on my State Water Heaters Water Heater?
    • R
      Robert BrennanAug 26, 2025
      If the self-diagnostic check has detected a problem with the black resistor wire on the igniter assembly plug (resistor wire is open or shorted), turn off the power to the water heater. Ensure the black resistor wire is not cut, missing, and is installed between pins 3 & 4 of the igniter assembly plug. Replace the igniter assembly if it is damaged or defective. If the error code persists, replace the gas control valve/thermostat.
  • S
    Suzanne BarronAug 28, 2025
    How to fix resistance of the black resistor wire on State Water Heaters Water Heater?
    • S
      Sheila Patel MDAug 29, 2025
      If the self-diagnostic check has determined that the resistance of the black resistor wire on the igniter assembly plug is not within tolerance, turn off the power to the water heater. Replace the igniter assembly plug. If the error code persists, replace the gas control valve/thermostat.
  • D
    Darryl GonzalezSep 1, 2025
    How to correct reversed polarity in my State Water Heaters GS675HRVIT Water Heater?
    • W
      wilkersonrachelSep 1, 2025
      If the gas control valve/thermostat has sensed reversed polarity in the 120 VAC power supply, ensure the wall outlet/power supply is properly wired. Also, ensure all internal 120 VAC wiring connections and wiring harnesses have no reversed wires, and that the 120 VAC "hot" wire connects to the on/off switch.
  • A
    Anthony ThomasSep 4, 2025
    What to do if the pressure switch circuit remains closed too long in my State Water Heaters Water Heater?
    • D
      Debra StoutSep 4, 2025
      If the pressure switch circuit remains closed for more than 5 seconds after the heating cycle begins, ensure the air pressure switch circuit wiring is correct and the air pressure switch is not jumpered. If the issue persists, replace the air pressure switch.
  • D
    Dustin NewmanSep 7, 2025
    Why does the air pressure switch circuit open repeatedly on my State Water Heaters GS675HRVIT Water Heater?
    • E
      Ernest WhiteheadSep 8, 2025
      If the gas control valve/thermostat has detected the air pressure switch circuit is opening repeatedly during one heating cycle, ensure the air pressure switch hose is not kinked or clogged and that the blower housing is clear of any condensation. Check the vent temperature limit switch; if it is opening its contacts at normal operating temperatures during the heating cycle, replace it. Also, ensure the water heater is not over-firing.
  • K
    Kristen OlsenSep 12, 2025
    What causes the pressure switch circuit to remain open on my State Water Heaters Water Heater?
    • B
      Brianna ValenzuelaSep 12, 2025
      If the pressure switch circuit remains open longer than 5 seconds after the blower is energized, ensure the air pressure switch sensing tube is properly connected at both ends and is not kinked or damaged. Also, ensure the correct size of vent and intake air pipe was used per the installation instructions in the manual that came with the water heater. Verify that the maximum number of elbows or maximum equivalent feet of vent or intake air pipe has not been exceeded per the installation instructions in the manual that came with the water heater, and make sure there are no obstructions in the vent or intake air pipe.

Summary

Safe Installation, Use and Service

Important Definitions

Key terms and roles for water heater installation and service.

General Safety

Introduction

Preparing for the Installation

Essential steps and considerations before beginning water heater installation.

Installation Requirements for the Commonwealth of Massachusetts

Typical Installation

Mixing Valve Usage

Guidance on using mixing valves for safe hot water temperature control.

Locating the New Water Heater

Facts to Consider About the Location

Critical factors for choosing an appropriate and safe installation location.

Combustion Air and Ventilation for Appliances Located in Confined Spaces

Requirements for ensuring adequate air supply for combustion in confined spaces.

Installing the New Water Heater

Chemical Vapor Corrosion

Warning about corrosive vapors affecting the water heater's lifespan.

Water Piping

Instructions and warnings regarding water connections and piping.

Thermal Expansion

Explanation of thermal expansion and its impact on closed water systems.

Gas Piping

Venting System

Sediment Traps (Drip Legs)

Importance and installation of sediment traps in gas piping.

Filling the Water Heater

Procedure for properly filling the water heater tank before operation.

Vent Pipe Termination

Guidelines for the proper termination point of the venting system.

Planning the Vent System

Condensate

Blower Assembly Installation

Vent Terminal Installation, Sidewall

Installation of Vent System, Sidewall

Installation of Vertical Vent System

Procedures for installing vertical vent systems through the roof.

Vent Pipe Preparation

Selection of Materials

Tools and materials required for vent pipe joining.

Primer and Cement Application

Proper use of primer, cement, and applicators for solvent welding.

For Your Safety Read Before Operating

Operating Instructions

Step-by-step guide for safely starting and operating the water heater.

To Turn Off Gas to Appliance

Instructions for safely shutting down the gas supply to the appliance.

Temperature Regulation

For Your Information

Thermal Expansion

Explanation of thermal expansion and its effects on water systems.

Operational Conditions

Discusses normal operating conditions like smells and sounds.

High Water Temperature Shut Off System

Information on the automatic safety feature for high water temperatures.

Periodic Maintenance

Venting System Inspection

Guidelines for visually inspecting the venting system annually.

Burner Operation and Inspection

Procedures for inspecting burner performance and flame characteristics.

Burner Cleaning

Steps for cleaning the burner and air openings for optimal performance.

Housekeeping

Basic cleaning recommendations for the area around the water heater.

Service

Leakage Checkpoints

Guide to identifying and correcting potential water leaks in the unit.

Repair Parts List

Troubleshooting Guidelines

Intelli-Vent Troubleshooting Chart - User Control

Diagnostic chart for troubleshooting issues using LED status codes.

Limited Residential Gas Warranty

Conditions and Exceptions

Terms and conditions that apply to the residential gas water heater warranty.

Service and Labor Responsibility

Clarifies owner responsibility for labor and incidental costs not covered by warranty.

Claim Procedure

Steps for initiating and processing a warranty claim.

State Water Heaters GS675HRVIT Specifications

General IconGeneral
BrandState Water Heaters
ModelGS675HRVIT
Capacity75 gallons
Energy Factor0.67
First Hour Rating90 gallons
Fuel TypeNatural Gas
Diameter24 Inches
TypeGas Water Heater
Warranty6 years
Input75, 000 BTU