Assembly:
Ensure that device is discon-
nected during assembly.
Attach straight tubes to
bent sections and screw in
place with 4 screws.
Operation:
The device has 3 air speeds „O - 1 - 2 - 3“ and can be swivelled by 90°.
Winter: Swivel the exhaust opening so that it is pointing at the ceiling and move the
switch to position „1. This will create circulation, and temperature differences in the
room will be balanced out.
Summer: Swivel the device to a horizontal or slightly angled position and move the
switch to position „2 - 3“. Do not position the intake near an outside door - otherwise
cold air may be blown into the room.
Information requirements
Steba VT 3
Description Symbol Value Unit
Maximum fan flow rate F 21,5 m
3
/min
Fan power input P 62,9 W
Service value SV 0,34 (m
3
/min)/W
Standby power consumption P
SB
0,0 W
Fan sound power level L
WA
63 dB(A)
Maximum air velocity c 3,9 meters/sec
Measurement standard for service value IEC 60879:1986(CORR.1992)
Contact details for obtaining more informa-
tion
Steba Elektrogeräte GmbH & Co.KG
Pointstr. 2
96129 Strullendorf