7 Safety Instructions
The UV system should be installed only according to above installation instruction. The external electrical cable of
this apparatus cannot be replaced. If the cable is damaged, the apparatus must be destroyed. Always switch off
the unit if there is no water running through it to prevent overheating. The power supply must be switched off im-
mediately if the apparatus or the electrical cord should become damaged.
Many local codes require that a Ground Fault Circuit Interrupter (GFCI) be installed in a branch circuit supplying
fountain equipment rated above 15 volts AC. GFCI’s are available through electrical and building supply stores,
catalogs, and contractors. Many new homes may already be equipped with a GFCI due to local codes.
Remember that UVC radiation is dangerous to the eyes and skin! Do not look directly at the unshielded bulb as
damage to the eyes may occur.
8 Maintenance
In order to keep the UVC apparatus working properly you must clean the intake and discharge connections and
the quartz sleeve (2) 2-3 times a year. To do this, first switch off the power supply to the UVC apparatus and to
the pump unit. Carefully remove the quartz sleeve from the bulb and cap, cord assembly. Wash the quartz sleeve
with lukewarm soapy water and rinse thoroughly. Remove any lime scale with vinegar, and rinse thoroughly. (It is
important that you do not touch the UV light bulb; the small amount of oil that is naturally on your skin will ruin the
bulb. If you do touch the bulb, clean it with rubbing alcohol before resuming service). The effective service life of
the UVC lamp is approx. 4000 burning hours. If used continuously the UVC lamp will therefore last for an entire
pond/pool season. We recommend that you replace the UV bulb every spring.
9 Additional Maintenance Tips
When carrying out any maintenance the unit must be unplugged from the electrical outlet. Always remove the in-
take and discharge hoses and drain the water before cleaning. When algae densities are very high in your pond
the unit should be cleaned regularly every 3-5 days until the problem is under control. When reassembling make
sure the o-rings are properly seated on the quartz sleeve. A small amount of petroleum jelly can be used for lubri-
cation if necessary. The UVC bulbs should be replaced every season to guarantee efficient operation. During the
winter season when temperatures fall below 50 degrees F (December to mid-March) you should remove the ap-
paratus to prevent it from freezing.
10 Warranty
This product is tested before delivery, if properly used and maintained, it offers you years of satisfaction. In the
unfortunate event that our material or our professional work should show defects during the warranty period,
please contact your local dealer. The warranty is invalid in case of:
1) The plant was dismantled
2) Flammable liquids, solvents, chemicals or abrasive solutions are being pumped