- 10 - - 11 -
Translation of the original operating instructions
GB
During installation, the
electrical wiring you are
connecting must be dead.
Therefore, switch off the
power first and use a volt-
age tester to make sure the
wiring is off circuit.
Installing this unit involves
work on the mains voltage
supply. This work must
therefore be carried out by
a qualified electrician in
accordance with applicable
national wiring regulations
and electrical operating
conditions (
D
- VDE 0100,
A
-ÖVE-ÖNORM E8001-1,
-SEV 1000).
Only use genuine replace-
ment parts.
Do not dismantle the unit
yourself. It must only be
repaired by a specialist
workshop.
Safety precautions
Installation
The IS 2360 is a sensor for mounting on indoor and outdoor ceilings.
L = live conductor (usually
black, brown or grey)
N = neutral conductor
(usually blue)
PE = any protective earth
conductor (green/yellow)
Note: Loop the protective-
earth conductor through if
necessary. A mains power
switch for turning the unit
ON and OFF may of course
be installed in the mains
supply lead.
Important: Reversing the
connections may result in
damage to the unit.
If ncecessary, the conden-
sation water drainage hole
must be drilled open with
a 5 mm drill bit.
Principle
Movement triggers lights,
alarms and many other de-
vices. For your convenience,
safety and peace of mind.
The integrated pyroelectric
infrared detector senses the
invisible heat radiated from
moving objects (people, ani-
mals, etc.). The heat detected
in this way is converted elec-
tronically into a signal that
switches ON the connected
load. Heat is not detected
through obstacles, such as
walls or panes of glass, and
will therefore not activate the
light.
System Components
Wall mount
Load module with lens
Designer trim
Sealing plug
Light-level setting
Time setting
Condensation water
drainage hole
Concealed wiring
Surface wiring
Functions
Light-level setting
(Factory setting: daylight operation 2000 lux):
The sensor's response threshold can be infinitely varied from
2 – 2000 lux.
Control dial set to
= daylight operation approx. 2000 lux.
Control dial set to
= twilight operation approx. 2 lux.
To adjust the detection zone in daylight, the control dial must be
set to
(daylight operation).
–
Time setting
(Factory setting: 8 sec.)
Light ON duration can be infinitely varied from 8 sec. to 35 min.
Control dial set to
– = shortest time (8 sec.)
Control dial set to + = longest time (35 min.)
When setting the detection zone, it is recommended to select
the shortest time
–.
Declaration of Conformity
This product complies with
- Low-Voltage Directive 2006/95/EC
- EMC Directive 2004/108/EC
- RoHS Directive 2011/65/EC
- WEEE Directive 2012/19/EC
2 – 2000 lux
8 sec. – 35 min.
GB