EasyManua.ls Logo

Steiner DBAL-I2 - Troubleshooting Beam Function Issues

Steiner DBAL-I2
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER IV SECTION II TROUBLESHOOTING
4.2 GENERAL
The purpose of troubleshooting is to identify the most frequent equipment
malfunctions, probable causes, and corrective actions required. Table 4-2 lists
the common malfunctions which may be found during the operation or mainte-
nance of the DBAL-I
2
and accessory equipment. Perform the tests, inspections
and corrective actions in the order listed. This manual cannot list all malfunctions
that may occur; or all tests, inspections and corrective actions.
Table 4-1 Preventive Maintenance Checks and Services
Malfunction Test / Inspection Corrective Action Ref. Para.
1. POINT/ILLUM a. Ensure Activation Mode -Properly align switch. 3.2.b
beams fai to come Selector Switch is in proper
on or stay on. position.
b. Verify Exit Port Cover is -Remove Exit Port 4.3.b
removed and that the Exit Port Covers.
Lens is not obscured by -Clean POINT/ILLUM
mud/dirt. Exit Port Lenses.
c. Verify battery installation. -Tighten battery cap. 3.2.a
-Install new battery
d. Inspect battery cap for damage -Notify Unit Maintenance.
or corrosion.
61