4.3.f Battery Removal and Replacement
Refer to Chapter III, Paragraph 3.2.a for Battery Installation procedures. No
special tools or equipment are required to replace the battery.
4.3.g Replace Remote Cable
Before each use, inspect the remote cable port for dirt, dust, or corrosion.
Thoroughly clean the receptacle by flushing with water, then wipe with a soft
cloth or disposable applicator.
4.3.h Battery Compartment O-ring
NOTE
Never use a sharp or metal object to remove O-rings, as they damage the
O-ring or the O-ring groove contact surface.
Before each use, inspect the battery compartment O-ring for nicks, cuts or
damage. Lubricate the O-ring as needed using silicone grease as follows:
1. Remove the O-ring. Be careful not to stretch the O-ring.
2. Check the O-ring for hair, sand, lint, or other debris and wipe clean as
necessary. Be careful not to stretch the O-ring. If the O-ring is cut or cracked
it must be removed and replaced with a new O-ring.