Reanimator F 120 Infant Transport System
GLOBETROTTER
®
trained personal only
Pursuant to Medical Device Directive 93/42, the apparatus must only be operated by
trained personnel. Prerequisite is an exact knowledge of the operating instructions!
The F. STEPHAN GmbH will not be liable for damages caused by faulty operation due to
non-observance of the operating instructions or from use for which the apparatus is not
earmarked.
STEPHAN
®
cmH O
2
-10
0
10
20
30
40
50
60
Überlastgrenze: 600 cmH O
Beatmungsdruck
2
STEPHAN
®
0
100
200
300
315
kPa x 100
bar
STEPHAN
®
0
8
6
4
2
10
kPa x 100
bar
Med.
AIR
1
5
10
1
5
10
L/min
1.013 bar
20°C
0 0
5
0
0
0
5
3
2
8
9
15
+
+
+
%
CAL
21%
INSPIRATION
O
2
O
2
O
2
AIR
OFF
EXPIRATION
(sec)
FREQUENCY
CABLE MAINS BA
T
PATIENT
Flow
L/min
O
Vol %
2
O
2
O
2
O
2
O
2
O
2
AIR
AIR AIR AIR
AIR
2 4 6 8
10
21
30
40
50
60
70
80
90
100
MAX
120
/min
TIMER
O
2
MIN
O
2
MAX
O
2
MONIT
OR
MONITOR
ON
/ OFF
AUT
O
TEST
CP
AP
HEATER
IMV
2 min
I
0
DISCONNECT
.
MAINS
12V ext.
BAT.
STENOSIS
O - ALARM
2
REANIMATOR F120
0 2 0 4 0 6 0 8 0 1
0
0,25 1,75 0,5 3,5 0,75 5,25 1 7 1,25 8,75
Hill-Rom
A HILLENBRAND INDUSTRY
0,5 1,5 1 3 1,5 4,5 2 6 2,5 7,5
0,75 1,25 1,5 2,5 2,25 3,75 3 5 3,75 6,25
1 1 2 2 3 3 4 4 5 5
1,25 0,75 2,5 1,5 3,75 2,25 5 3 6,25 3,75
1,5 0,5 3 1 4,5 1,5 6 2 7,5 2,5
1,75 0,25 3,5 0,5 5,25 0,75 7 1 8,75 1,25
2 0 4 0 6 0 8 0 10
0
MENUE
0
2 min
POSITION
OF
ELECTRODES
APNEA
- CARDIAC - SpO MONITOR
2
-
NeoSID NOV
A
PLUS
SET
Air-Shields
R
R
STEPHAN
®
cmH
O
2
-10
0
10
20
30
40
50
60
Überlastgrenze: 600 c
mH O
Beatmungsdruck
2
0 0
5
0
0
0
5
3
2
8
9
15
+
+
+
%
CAL
21%
INSPIRATION
O
2
O
2
O
EXPIRATION
(sec)
FREQUENCY
MAX
120
/min
TIMER
O
2
MIN
O
2
MAX
MONITOR
ON
/ OFF
AUTO
TEST
CP
AP
HEATER
IMV
2 min
I
0
DISCONNECT
.
MAINS
12V ext.
BAT.
STENOSIS
O - ALARM
2
REANIMATOR F120
Hill-Rom
A HILLENBRAND INDUSTRY
Air-Shields
R
IMV
default mode at start
2 min
suppression
Battery only
NOVA
mains alarm
only NOVA
menu key to
move up or
down
patient alarm
blinks at cardiac or
respiratory alarm
cable alarm
blinks at failure of patient
cable or xation of elec-
trodes
2 min alarm
suppression
for NOVA
Display of frequency
three „---“ in CPAP mode
blinks if out of possible
range max. 120/min (IMV
Mode)
Inspiration
0,25 - 2,00s
Expiration
0,25 - 30,00s
Oxygen owmeter for aux
outlet for incubator
O2 pressure
internal
O2 pressure
cylinder/
content
aux. O2 connector for
incubator
O2 sensor in normal posi-
tion removable for use in
incubator. Close the socket
with replacement plug if cell
is outside (prevents high
leakage ow)
manual ventilation with
prexed patterns PEEP
PLATEAU
manual ination
ll bottle with Aqua Dest.
(sterile and demineralised
water) not over max. level!
Reduce level, if ow is
higher than 10l/min!
Water is sufcient for 4-6 h
LED for
Stenosis Visual alarm if the
permanently installed pressure
of 12 mbar is not fallen below 2,2
seconds after the set end of inspi-
ration time (stenosis)
Disconnection Visual alarm
ensues if the permanently installed
pressure limit of 12 mbar is not
execeeded after the set expiration
time +max inspiration time (2.0s)
O2 Alarm Visual alarm in case of
violation of the set limit values for
O2 concentration (monitor must be
switched ON)
Battery Visual and acoustic alarm
if internal battery voltage falls
below 10,8V. Heater is off.
Every 30s warning tone occurs not
suppressable. 20 minutes remai-
ning then respirator is shut off
Turn OFF:
Press key,
press additional key,
unhand red key
brief instruction F120 GT ver 1.0 1
23.08.02 JS
Question and Answer IconNeed help?

Do you have a question about the Stephan Reanimator F 120 and is the answer not in the manual?

Stephan Reanimator F 120 Specifications

General IconGeneral
BrandStephan
ModelReanimator F 120
CategoryMedical Equipment
LanguageEnglish

Summary

General Safety and Operation Guidelines

Safety Warnings and Liability

Apparatus must be operated by trained personnel; manufacturer not liable for faulty operation.

Reanimator F120 Controls and Indicators

Breathing Parameters and Modes

Settings for inspiration, expiration, and manual ventilation patterns.

Pressure and Flow Indicators

Displays for breathing pressure, O2, AIR flow rates, and overload limits.

Alarm Indicators and Suppression

Visual alarms for stenosis, disconnection, O2 concentration, and battery status.

Setup and Maintenance Notes

Instructions for filling water bottle and O2 sensor placement.

External Connections and Power Supply

Power Input and Charging

Connecting to 230V supply for operation and internal battery charging.

Auxiliary Connections

Reception coupling for O2/air, 12V external supply, RS 232, and potential bonding.

Patient Monitoring and Alarms

Electrode Placement and Connection

Guidance on placing electrodes and connecting to the patient cable.

Displayed Parameters and Alarms

Information on heart rate, respiratory frequency, time, and various alarm symbols.

Related product manuals