2–40 hp Portable Chillers
Part Number: A0554831
Bulletin Number: SC2-610C.10
Effective: 4/3/2008
Write Down Your Serial Numbers Here For Future Reference:
_________________________ _________________________
_________________________ _________________________
_________________________ _________________________
We are committed to a continuing program of product improvement.
Specifications, appearance, and dimensions described in this manual are subject to change without notice.
DCN No. ____________
© Copyright 2008
All rights reserved.

Table of Contents

Questions and Answers

  • S
    Sean BakerJul 29, 2025
    How to troubleshoot a Sterling A0554831 Chiller that does not run?
    • Y
      Yolanda YangJul 29, 2025
      If your Sterling Chiller isn't running, there are several potential causes: * **No power:** Check the main disconnect, fuses, wiring, and the power lead to the unit. * **Wrong voltage:** Ensure the voltage supplied is within plus or minus 10% of the nameplate rating. * **Defective on/off switch:** Consider replacing the switch. * **Blown control circuit fuse:** Replace the control circuit fuse. * **Other issues:** Check the transformer and look for any short circuits. * **Defective control transformer:** Replace it if necessary. * **Open piping flow switch circuit:** Add water or a water/glycol solution as needed. * **Pump motor overload:** Reset and test the pump motor.
  • M
    Mrs. Sabrina MartinezAug 7, 2025
    Why is my Sterling A0554831 Chiller running continuously but not providing enough cooling?
    • J
      Jeff DennisAug 7, 2025
      If your Sterling Chiller runs continuously but doesn't provide enough cooling, check the following: * **Restricted condenser air:** Clean the filters and the condenser. * **Low refrigerant:** Check the refrigerant charge. * **Compressor inefficiency:** Call service to assess the compressor's operation. * **Undersized unit:** Call sales rep.
  • D
    Diana HicksAug 11, 2025
    What causes the water temperature to be too high in a Sterling A0554831 Chiller?
    • H
      hknoxAug 11, 2025
      If the water temperature is too high in your Sterling Chiller, consider these factors: * **Inadequate water/glycol mixture:** Ensure the water/glycol mixture provides adequate protection for the process. * **Defective thermostat:** Adjust or replace the High/Low thermostat if it's defective or improperly set. * **Refrigerant pressure switch setting:** Call service to adjust pressure control if the refrigerant low-pressure switch is set too high. * **Low refrigerant charge:** Call service to find and repair the leak, then have refrigerant added.
  • E
    Eric LesterAug 15, 2025
    What to do if Sterling A0554831 pump runs, but the compressor cycles at short intervals?
    • C
      cody36Aug 15, 2025
      If the pump runs, but the compressor cycles at short intervals, then: * Clean the plugged Y-Strainer. * Replace relay board on control bed hot gas coil if hot gas is not coming on. * Install bypass between to-and-from process line if there is low water flow.
  • P
    Patricia BaileyAug 19, 2025
    How to reduce high pump pressure in a Sterling A0554831 Chiller?
    • C
      chloefernandezAug 19, 2025
      If the pump pressure is too high, it might be due to restricted water flow. Check for partially closed valves and ensure all lines are properly sized.
  • A
    Ashley VaughnAug 25, 2025
    Why is the pump pressure low in my Sterling A0554831?
    • D
      daniel00Aug 25, 2025
      If the pump pressure is low, consider these possibilities: * **Reverse pump operation:** Verify the pump's rotation. If it's running in reverse, reverse any two main power leads and re-verify correct rotation. * **Foreign matter:** Clean the system to remove any foreign matter.
  • D
    Daniel GilesNov 1, 2025
    What to do if the pump runs but the compressor doesn't in my Sterling Chiller?
    • R
      Robert Campbell MDNov 1, 2025
      If the pump runs but the compressor doesn't, consider these potential causes: * **Thermostat setting:** Ensure the High/Low thermostat isn't set higher than the liquid temperature in the system. Lower thermostat stage 1 set to 10°F (6°C) below the leaving temperature you want. * **Defective thermostat:** Replace the High/Low thermostat if it's defective. * **Low refrigerant:** Check the refrigerant charge. * **Refrigerant pressure:** If the refrigerant low pressure switch contacts are open, the sight glass should be clear and the moisture indicator should be green while the compressor is running. If bubbling is occurring and/or the moisture indicator is yellow, call for service. * **High-pressure indicator:** Clean the air filters. * **Other issues:** Check condenser fans for ...

Summary

Shipping Information

Unpacking and Inspection

Inspect equipment for shipping damage, check for broken or loose wiring, components, hardware, etc.

Handling Shipping Damage

Procedure for handling shipping damage claims with the carrier, including documentation and notification.

Shipment Completeness and Accuracy

Checklist for missing items and instructions for incorrect shipments.

Chapter 1: Safety

How to Use This Manual

Guide for installing, operating, and maintaining equipment, covering maintenance, installation, operation, troubleshooting, and appendix.

Warnings and Precautions

Safe practices for installing, operating, and maintaining equipment to avoid injury or damage.

Responsibility

Operator's responsibility for safe operation, adhering to rules, and reporting hazards.

Chapter 2: Functional Description

Models Covered and General Description

Manual covers chillers; describes general features, chilled water, and refrigeration circuits.

Standard Features Overview

Details mechanical, electrical, refrigeration, and controller features common to all models.

Safety Devices and Interlocks

Describes safety devices like thermostats, pressure cutouts, and flow/pressure switches.

Optional Features and Configurations

Lists and describes various optional features and configurations like make-up, filters, alarms, comms, fans, and reservoirs.

Chapter 3: Installation

Uncrating Procedures

Step-by-step instructions for removing the chiller from its shipping container and skid.

Electrical Connections

Guidance on supplying power, connecting leads, and ensuring tight electrical connections.

Water Connections and Considerations

Connecting process water lines, bypass valve, galvanic corrosion, and water treatment.

Condenser Installation and Considerations

Details for water-cooled and air-cooled condensers, including connections and cleaning.

Remote Condenser Piping and Configuration

Handling refrigerant piping for remote condensers, including sizing and installation.

Refrigerant and Oil Charge Determination

Methods for determining refrigerant and oil charge based on system configuration.

Motor Direction and Pump Checks

Procedures for checking motor rotation, pump operation, and condenser fan airflow.

Water Reservoir and Make-Up Systems

Details on water reservoir management and automatic make-up options.

Initial Start-Up Procedures

Checklist for verifying chiller configuration and performing initial startup.

Chapter 4: Operation

Control Panel Interface Overview

Explains the functions of buttons, LEDs, and indicators on the control panel.

Microprocessor Controller Operation

Details the operation of E5CK and Sterlco 2000 controllers, including indicators and keys.

Graphic Panel Indicators and Controls

Describes indicator lights and switches on the chiller's graphic control panel.

Start-up and Temperature Setting

Steps for starting the chiller and setting process water temperatures.

Auto-Tuning and Communications

Procedures for PID auto-tuning and setting up optional communications.

Thermostat Programming

Instructions for programming the electronic high/low thermostat settings.

Chapter 5: Maintenance

Lubrication and Filter Cleaning

Procedures for lubricating motors/fans and cleaning air filters for optimal performance.

Condenser and Evaporator Maintenance

Cleaning heat exchange surfaces in condensers and evaporators, including Y-strainer.

Preventative Maintenance Service

Overview of systematic maintenance checks to avoid downtime, including various inspections.

Chapter 6: Troubleshooting

Unit Does Not Run

Discusses potential causes and solutions for the unit failing to start.

Pump Runs, Compressor Does Not

Addresses issues where the pump operates but the compressor remains inactive.

Common Operational Issues

Troubleshooting for pump cycling, high water temp, pressure issues, and insufficient cooling.

Chapter 7: Appendix

Returned Material Policy

Details policies for credit returns and warranty returns, including authorization and shipping.

Technical Assistance Contacts

Contact information and services for Parts, Service, Sales, and Contract departments.

Drawings and Specifications by Model

Provides dimensional data, specifications, and performance parameters for chiller models.

Pump Curves and Pressure Considerations

Information on pump performance curves and flow/pressure considerations.

Piping Diagrams and Configurations

Diagrams illustrating various piping configurations and schematics.

Electrical Schematics

Section covering electrical schematics for the unit.

Sterling A0554831 Specifications

General IconGeneral
BrandSterling
ModelA0554831
CategoryChiller
LanguageEnglish