4
The manufacturer has set the water treatment unit’s sequence of cycles, cycle times, salt dose, exchange
capacity and gallon capacity. The salt dose refill time has been preset.
The dealer should read this page and guide the installer regarding hardness, day override, and time of
regeneration, before installation:
For the installer, the following sections should be read:
Set Installer Settings… Hardness (preset to 20 gpg), Day Override (preset to 3 days),
and Time of Regeneration (preset to 2 am).
Normal Operating Displays
Set Time of Day
Power Loss & Error Display
Water Softeners:
During operation, the normal user displays are time of day, gallons per minute or gallons remaining before
regeneration will occur. Each of these can be viewed by pressing NEXT to scroll through them. When stepping
through any displays or programming, if no buttons are pressed within 5 minutes, the display returns to a normal
user display. Any changes made prior to the 5 minute time out are incorporated.
If desired, two regenerations within 24 hours are possible with a return to the preset program. To do a double
regeneration:
1. Press the REGEN button once, REGEN TODAY will flash on the display.
2. Press and hold the REGEN button for five seconds or until a regeneration begins.
Once the valve has completed the immediate regeneration, the valve will regenerate one more time at the pre-
set time.