• Do not expose the pump to frost.
• Do not operate the pump without water.
• Never carry the pump by its cable, nor pull on the cable to
unplug it.
• Do not modify the interior of the pump.
• While the pump is running, do not touch the pump, as well as
objects in contact with the water (for example, objects in the
water, railings, etc.).
• Water that has been delivered with this appliance is no drinking
water
• Do not pump greases, oils and salt water.
• Do not pump waste water from sanitary faci
lities and silty
water with a lower flowability than clear water.
• Do not pump water
that has a higher temperature than 35°C.
2.8 RESIDUAL RISKS
• There are no additional residual risks associated with the use,
maintenance and transport of this product.
3. TECHNICAL DATA
Surface pump model 250 TP-3
Power rating 250W
Electric voltage / Electrical frequency 220V-240V / 50Hz
Maximum starting current 2.66 A
Maximum working current 1.21 A
Capacitor parameters(capacity / maximum
voltage)
8 μF/450v
Insulation class F
Motor rotation frequency 2900rpm