POS PART NUMBER DESCRIPTION NUM
29 GB845 ST4.2×18-F Cross head tapping
screw
3
30 GB845 ST4.2*24 Cross head tapping
screw
1
31 JHCT041.05.031 Ground cover 1
32 JHCT041.01.001 Nylon safety wire
pressing cap
2
32 JHCT041.01.003 Nylon safety wire
pressing cap
3
33 JHCT085.01.001 Tie 1
34 JHCT078.02.021 Tapping screw 1
35 JHCT051.01.079 O ring 1
36 JHCT032.04.058 Sand prevention ring 1
37 JHCT043.04.014 Ring gasket 1
38 JHCT032.06.012 Rubber plug 1
JHCT105.01.001 Motor oil 0,012
JHCT105.01.013 White oil 2.5ML
8.4
TROUBLESHOOTING
DANGER ! Risk of injury due to electric shock, re and/or
serious injury. Warning ! Before any trouble shooting, switch
o the product and keep other person away.
Problems Probable causes Solutions
Qualication
required
The pump is not
starting
- There is no electric current
- The oater switch is in
the low position (current
switched o)
- The oater mechanism is
blocked.
- Ensure that the electric
current is on.
- Raise the oater
- Shake the oater
- Check the water height
No qualication
required
The pump is not
draining
- The intake pipe is clogged
- The outlet pipe is clogged
- The turbine is blocked
- Presence of an air bubble
- Clean the intake pipe
- Clean the pipe
- Disassemble the base and
clean the turbine
- Tilt the pump to let out the
air bubble then put it back in
vertical position
No qualication
required