TECHNICAL SPECIFICATIONS 15
EN
Maximum noise and vibration levels
Model
B
28
BJ 326
BJC 326
B
28 J
SB 28 J
B 28 D
B 28 JD
S
B 28 JD
B 33
BJ 336
B
JC 336
B
33 D
SB 33 D
B 44
BJ 346
B
JC 346
B
44 D
SB 44D
Operator ear noise pressure level (EN ISO 22868)
with line cutter head
dB(A)
102 102 102 102 99 99
Measurement uncertainty (2006/42/EC - EN 27574)
d
B(A)
3 3 3 3 3 3
with 3-point blade
d
B(A)
95 95 97 97 100 100
Measurement uncertainty (2006/42/EC - EN 27574)
dB(A)
3 3 3 3 3 3
Measured sound power level (EN ISO 22868)
with line cutter head
dB(A)
111 111 113 113 109 109
Measurement uncertainty (2006/42/EC - EN 27574)
dB(A)
3 3 3 3 3 3
with 3-point blade
dB(A)
105 105 106 106 111 111
Measurement uncertainty (2006/42/EC - EN 27574)
dB(A)
3 3 3 3 3 3
Vibrations transmitted to the hand on the front handgrip (“MONO”) (ISO 22867)
with line cutter head
m/sec
2
7.87 – 5.57 – 6.36 –
Measurement uncertainty (2006/42/EC - EN 12096)
m/sec
2
1.5 – 1.5 – 1.5 –
with 3-point blade
m/sec
2
2.24 – 4.3 – 2.82 –
Measurement uncertainty (2006/42/EC - EN 12096)
m/sec
2
1.5 – 1.5 – 1.5 –
Vibrations transmitted to the hand on the rear handgrip (“MONO”) (ISO 22867)
with line cutter head
m/sec
2
5.09 – 4.25 – 2.84 –
Measurement uncertainty (2006/42/EC - EN 12096)
m/sec
2
1.5 – 1.5 – 1.5 –
with 3-point blade
m/sec
2
7.61 – 3.56 – 2.86 –
Measurement uncertainty (2006/42/EC - EN 12096)
m/sec
2
1.5 – 1.5 – 1.5 –
Vibrations transmitted to the hand on the left handgrip (“DUPLEX”) (ISO 22867)
with line cutter head
m/sec
2
– 1.76 – 4.36 – 5.62
Measurement uncertainty (2006/42/EC - EN 12096)
m/sec
2
– 1.5 – 1.5 – 1.5
with 3-point blade
m/sec
2
– 0.432 – 3.6 – 1.94
Measurement uncertainty (2006/42/EC - EN 12096)
m/sec
2
– 1.5 – 1.5 – 1.5
Vibrations transmitted to the hand on the right handgrip (“DUPLEX”) (ISO 22867)
with line cutter head
m/sec
2
– 3.19 – 5.06 – 2.41
Measurement uncertainty (2006/42/EC - EN 12096)
m/sec
2
– 1.5 – 1.5 – 1.5
with 3-point blade
m/sec
2
– 0.356 – 4.38 – 0.66
Measurement uncertainty (2006/42/EC - EN 12096)
m/sec
2
– 1.5 – 1.5 – 1.5

Table of Contents