0458-824-8621-B
27
English
23 Troubleshooting Guide
Blower cuts out
during operation.
1 LED glows
red.
Battery too hot / too
cold.
► Remove the battery, @ 14.2.
► Allow the blower and battery to cool down gradually at
ambient temperatures of about 50 °F to 68 °F (10 °C to
20 °C).
3 LEDs glow
red.
Blower too hot.
Run-time is too short. Battery not fully
charged.
► Charge the battery, @ 10.
Useful life of battery
has been reached or
exceeded.
► Have the battery checked by an authorized STIHL servicing
dealer.
Battery is not being
charged even though
LED on charger
glows green.
1 LED glows
red.
Battery too hot / too
cold.
► Allow the battery to warm up or cool down gradually at
ambient temperatures of about 50 °F to 68 °F (10 °C to
20 °C).
► Operate the charger only in enclosed, dry rooms at ambient
temperatures of 41 °F to 104 °F (5 °C to 40 °C).
Always remove the battery before carrying out any inspection, cleaning or maintenance.
Condition LEDs on
Battery
Cause Remedy