HLA 65
English
31
Running time is too short
Battery is not completely charged Charge battery
Service life of battery has been reached
or exceeded
Check battery
1)
and replace
Blade clogged/dirty Clean blades, spray with STIHL resin
solvent
Blade bent Have blade checked by a servicing
dealer
1)
Battery gets stuck during insertion in the
machine/charger
Guides dirty Carefully clean guides
Battery does not charge although the LEDs
on the charger are green
Battery too hot / too cold
(1 LED on battery is red)
Let the battery cool down / let the battery
warm up gradually at temperatures of
approx. 15 °C - 20 °C (59°F - 68°F)
Operate the charger only in a closed, dry
space at ambient temperatures of +5 °C
to +40 °C (41°F - 104°F)
LED on charger flashes red
No electrical contact between charger
and battery
Remove battery and reinsert it
Battery fault
(4 LEDs on battery flash red for
approx. 5 seconds)
Remove battery from the machine and
reinsert it. Turn on the machine – if the
LEDs still flash, the battery is faulty and
must be replaced
Fault in charger Have charger checked by a servicing
dealer
1)
1)
STIHL recommends STIHL servicing dealers
Always remove the battery from the machine before starting any work on the machine.
Fault Cause Remedy