15 Troubleshooting
15.1 Correcting faults on the wet/dry vacuum cleaner
15 Troubleshooting
Fault Cause Remedy
The wet/dry vacuum
cleaner does not start
when switched on.
The mains plug of the connecting cable or
extension cord is not plugged in.
Plug in the plug of the connecting cable.
The circuit breaker (fuse) or the overload cutout
has tripped. There is an electrical overload or a
fault in the circuit.
Look for cause of tripping and remedy it.
Insert circuit breaker (fuse) or overload
cutout.
Switch off other loads connected to the same
circuit.
The fuse rating of the socket is too low. Plug the connecting cable into a socket with
the correct fuse rating, @ 16.1.
The extension cord has an incorrect cross-
section.
Use an extension cord with an adequate
cross-section, @ 16.2
The extension cord is too long. Use an extension cord with the correct
length, @ 16.2
The wet/dry vacuum
cleaner switches off while
in operation.
The plug of the connecting cable or extension
cord has been pulled out of the socket.
Insert the plug of the connecting cable or of
the extension cord.
The circuit breaker (fuse) or the overload cutout
has tripped. There is an electrical overload or a
fault in the circuit.
Look for cause of tripping and remedy it.
Insert circuit breaker (fuse) or overload
cutout.
Switch off other loads connected to the same
circuit.
The fuse rating of the socket is too low. Plug the connecting cable into a socket with
the correct fuse rating, @ 16.1.
The suction power is too
low.
The filter bag or the container is full. Replace filter bag or empty the container.
The cartridge filter is dirty. Clean or replace the cartridge filter.
The container is full. The float is enabled. Empty the container.