EasyManua.ls Logo

Still LTX 70 - Page 143

Still LTX 70
186 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
To perform the operations described below,
the electrical supply to the tow tractor must be
cut off:
– Immobilise the tow tractor
– Switch off the ignition, and remove the key
– Press the emergency stop button
– Open the battery compartment door
– Unlock the battery
– Remove the battery from its compartment
using a suitable tool
Gel battery
– Check for traces of sulphate in the compart-
ment and frame
– If there is only minimal sulphate build-up,
just wipe the top of the cells with a damp
cloth
– If sulphate build-up is substantial, you must
jet wash the battery and clean the frame
Lead battery
– Check that there is no electrolyte in the bot-
tom of the compartment. To do this, con-
nect the suction bulb supplied with the bat-
tery to the plastic plunger tube
– Pump off any electrolyte that may have spil-
led between the cells
– Clean the top of the cells with a damp cloth
CAUTION
In the event of substantial sulphate build-up or ex-
cessive electrolyte spillage, please contact the after-
sales service department as soon as possible.
After these checks have been performed,
please lock the battery correctly and close the
battery compartment door.
Maintenance
5
Chassis, bodywork and fittings
1331191 801 15 51 EN - 02/2021 - 10