Note 1.
Self Test Procedure.
Fail = Buzzer sounds continuously.
Pass = Buzzer beeps several times, the number of beeps indicates the logic
board version number, e.g. 4 beeps for version 4 etc.
Note 2.
The hot gas solenoid is always opened for 15 seconds before starting the compressor,
this allows the gas pressures to equalise before the compressor starts.
Note 3.
Pushing the reset button during the initial start up defrost will cancel the defrost and place
the machine in normal ice making mode.
Note 4.
Bin Full is indicated by one or more of the ice curtains remaining open after an ice drop.
Note 5.
The correct quantity of water during fill is signalled by the high float switch, the water fills
until the top float switch operates. The water will continue to fill for a period of time after
reaching the high float. This is the purge time.
Note 6.
The clean timer is set for 3,000 hours, this timer is reset when the manual clean cycle
is activated.
Note 7.
The first time this error occurs the machine will restart at “Power Up” if the same error is
detected after Power Up the machine will shut down and the appropriate error number will
flash on the display.