1
SPECIFICATIONS
MODEL
WATER
PRESSURE
All Models Minimum: 140 kpa
Maximum: 560 kpa
OPERATING
TEMPERATURE
All Models Minimum: 1 degree Celsius
Maximum: 43 degrees Celsius
FAN PRESSURE
CONTROL (kpa)
Cut In
Cut Out
1660 1660 1660 1400 1660
1240 1240 1240 1100 1240
WATER
CONNECTION
REQUIREMENTS
All Models 3/4” BSP male stop cock
DRAINAGE
All Models 25mm diameter PVC
SC130 SC270 SC500 SC1000 SC2000
ELECTRICAL
REFRIGERATION
SUCTION
PRESSURE
@ 32deg. C
FLOODED
EVAPORATOR
240 volts
50 hz
3.8 amps
R-404A
450g
290kpa
240 volts
50 hz
8.0 amps
R-404A
940g
290kpa
240 volts
50 hz
12.0 amps
R-404A
1900g
290kpa
415 volts
50 hz
10 amps/ph.
R-22
4500g
215kpa
415 volts
50 hz
18 amps/ph.
R-404A
———
290kpa
ICE WEIGHT (Total both slabs)
SC130 SC270 SC500 SC1000 SC2000
1,500g 2,700g 5,400g 10,800g 21,600g
PURGE AMOUNT
200 mil 400 mil 500 mil 1000 mil 1000 mil