Spooling motors
For
dismantllng
and flttlng
the capstan
see under
C
6.
The ball-bearings
of the
spooling motors
have
a life
expectation
of
approxlmately 10,000
operating
hours.
After thls
period
of
tlme, the
ball-bearings
and the
approprlate oil. retainlng
felt rings
should be
replaced,
Other
additional olling
is not necessary
and should
therefore
be avoided.
lmportant:
All
other moving
parts
of the recorder
such
as the
guide
rollers
are
lubrlcated
for Iife
(
app.
20,000 hours
of operation)
and
need no
speclal
servicing. If any of the
bearings become
noisy
before this ]ength
of time, these
faulty
bearings
should be replaced.
The
order numbers
can be
found in the
spare
parts
llst.