Lists attached documents like electrical drawings and controller manuals.
Provides overview of unit design, quality, and compliance with regulations.
Safety precautions and guidelines for handling refrigerants.
Requirements for operating refrigerating plants within the EU.
Describes the arrangement of internal components for TLF, TLD, and TLU units.
Explains unit operation in Cooling, Free-cooling, Assisted free-cooling, and Heating.
Details the structure, air filter, drip-tray, and damper of the unit.
Describes the hermetic cooling circuit, compressor, condenser, and evaporator.
Details the compressor motor, fans, and damper servomotor specifications.
Explains safety switches, contactors, circuit breakers, and thermostats.
Specifies operating and storage limits for temperature and humidity.
Presents detailed technical specifications including electrical and performance data.
Guidelines for safely handling the unit during installation and servicing.
Safety measures for installation and maintenance personnel.
Instructions for correctly positioning the unit within the shelter, including clearance.
Guidance on connecting condensate drain pipes, ensuring proper flow.
Safety precautions and requirements for making electrical connections.
Outlines monthly, quarterly, and yearly maintenance tasks for the unit.
General safety rules for personnel involved in testing and maintenance.
Identifies hazards related to fan movement and heat exchanger edges.
Discusses electrical risks and safety standards.
Safety measures for working with refrigerants, including handling and fire risks.
Addresses fire risks associated with refrigerant gas and ventilation.
Information on toxic substances related to refrigerant leaks.
Details on condensate and potential hazards.
Describes a protective coating for heat exchangers to prevent corrosion.
Explains the optional electrical reheat for heating internal air.
Phase monitoring relay for compressor protection against sequence or phase loss.
Information on using R134a refrigerant for higher operating temperatures.
Option for operating the unit in very low outdoor temperatures down to -40°C.
Describes the main switch for disconnecting unit power supply.
Connectors for fast power supply connection.
Heater to keep compressor oil warm during low outdoor temperatures.
Device to reduce compressor starting current and torque.
Option to reduce starting current for single-phase compressors.
Device to stop power supply and prevent faults due to voltage deviations.
Ethernet interface for supervision, monitoring, and firmware updates.
Special wooden packaging suitable for sea freight.