IT Cooling Solutions
Index G20
Issue 1.2017
Mini-Space DX
Precision Air Conditioning Units
380-415/3/50
Original instructions
Question and Answer IconNeed help?

Do you have a question about the Stulz Mini-Space DX CCD131A and is the answer not in the manual?

Stulz Mini-Space DX CCD131A Specifications

General IconGeneral
BrandStulz
ModelMini-Space DX CCD131A
CategoryAir Conditioner
LanguageEnglish

Summary

1. Safety

Safety Instructions and Requirements

Covers general safety, handling refrigerants, and environmental requirements for safe operation.

5. Technical Data and Application Limits

5.1 Application Limits

Lists admissible operating conditions for temperature, humidity, ambient, storage, and piping.

5.2 Technical Data Tables

Presents detailed technical specifications for various unit models in tabular format.

6. Installation Guide

6.1 Positioning and Clearances

Guides on unit placement, required clearances for maintenance, airflow, and environmental restrictions.

6.3.1.2 Refrigerant Connection Positions (Downflow Models)

Shows refrigerant connection locations and dimensions for downflow unit variants.

6.3.1.2 Refrigerant Connection Positions (Upflow Models)

Illustrates refrigerant connection locations and dimensions for upflow unit variants.

6.3.1.2 Refrigerant Connection Positions (Large Downflow)

Provides refrigerant connection details and dimensions for larger downflow units.

6.3.1.2 Refrigerant Connection Positions (Large Upflow)

Details refrigerant connection locations and dimensions for larger upflow units.

6.3.1.3 Filling the Refrigerant Circuit

Provides a step-by-step guide for safely filling the refrigerant circuit with necessary precautions.

6.3.2 Water Piping Connections

Covers external water circuit setup, anti-freeze agent, and condenser water system recommendations.

6.3.3 Condensate Drain Connection

Explains syphon installation and condensate drain connections to the waste water system.

6.4 Electrical Connection

Details electrical connection procedures, safety measures, phase rotation, and power supply requirements.

7. Commissioning

Commissioning Steps and Checks

Guides through the commissioning process, including power checks, controller settings, and operational verification.

8. Maintenance Procedures

8.1 Safety Instructions and 8.2 Maintenance Intervals

Stresses safety precautions for maintenance and provides a schedule of recommended intervals for unit components.

8.3 Refrigerant Circuit Maintenance

Details refrigerant charge checks, leak detection, and safe charging procedures for R407C.

8.3 Refrigerant Circuit and 8.4 Air Circuit Maintenance

Covers compressor oil, expansion valve, heat exchanger, and air filter maintenance and checks.

9. Malfunction and Troubleshooting

10. Dismantling and Disposal

12.1 Steam Humidifier

12.1.4 Fault Elimination

Provides methods for troubleshooting and eliminating malfunctions based on LED indications.

12.1.4.4 Malfunction Lists

Details specific malfunctions, their causes, remedies, and associated LED blink codes.

12.2 Reheat Options

12.5 Electrical Options

12.6 Refrigerant Circuit Options