8INSTALLATIONHBASE STÛV16
2
.3 INSTALLING THE STOVE
Step 11 Slide the offset reducer onto the
cylindrical connector.
Step 12 Secure the cylindrical connector
and the reducer with the two self-drilling
screws provided.
Step 13 Connect the offset reducer to
the Ø4’’ outside air duct (not provided)
and secure with a clamping collar.
x2
131211
Step 14 In areas where winter
temperatures go bellow -10 °C / 14 °F, it
is mandatory that the duct leading to the
outside air have a minimum of 10' long.
It is recommended that you form a loop
with the flexible duct inside the wall.
An air damper is also recommended when
installing an outside air intake.
Step 15 Remove the air traps from the
Stûv 16 base plate. These items will not be
used in this installation.
10’
Air damper
14
Outisde air kit 4" air damper
AW12002000001 AW1200100300
15
7mm
T20