Dimensions to combustible materials Dimensions pour matériel combustibles
Note: L’installation de deux panneaux de fibro-ciment
de 1/2" est OBLIGATOIRE sous l’unité. La structure qui
supporte l’unité peut être faite de bois, en autant qu’elle
soit assez solide pour supporter le poids de l’unité et de la
cheminée.
Note: The installation of two layers of 1/2" cement board
under the unit is MANDATORY. The supporting structure
can be made of wood, providing it is strong enough to
support the weight of the fireplace and the chimney.
AB
Stûv 21/65H SF 31 7/8" 23"
Stûv 21/75 SF 35 3/4" 23"
Stûv 21/85 SF 39 3/4" 25"
Stûv 21/95 SF 43 5/8" 27"
Stûv 21/105 SF 47 5/8" 23 1/2"
Stûv 21/125 SF 55 1/2" 26 1/4"
Stûv 21/135 SF 59 3/8" ...
Stûv 21/75 DF 35 3/4" 26"
Stûv 21/85 DF 39 3/4" 26"
Stûv 21/95 DF 43 5/8" 26"
Stûv 21/125 DF 55 1/2" 26"
C = B + Wall thickness
C = B + épaisseur du mur