EasyManua.ls Logo

StyleCrest Revolv VMA3-50D36N - User Manual

StyleCrest Revolv VMA3-50D36N
65 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
STYLE CREST, INC.
2450 ENTERPRISE STREET
FREMONT, OH 43420
PHONE: (419) 332-7369
MG-518
ECN 0000-MA 151209
MADE IN USA
GAS FIRED HIGH EFFICIENCY FURNACE
DOWNFLOW & DIRECT VENT (SEALED COMBUSTION)
MODELS:
VMA3-50D36N, VMA3-75D36N,
VMC1-50D36N, VMC1-75D36N,
VMC1-50DV3N, VMC1-75DV3N
INSTALLATION AND SERVICE MANUAL
For installation in:
1. Manufactured Homes
2. Modular Homes/Buildings
3. Site Constructed—Residential (Single Story Dwellings)
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
:
If the information in these instructions is not followed exactly, a fire or explosion may
result causing property damage, personal injury, or loss of life.
: Improper installation, adjustment, alteration, service, or maintenance can cause injury or
property damage. Refer to this manual. For assistance or additional information, consult a qualified
installer, service agency, or fuel supplier.
: Do not use this appliance if any part has been underwater. Immediately call a qualified
service technician to inspect the appliance and to replace any part of the electrical or control system
that has been underwater.
PLEASE READ THESE INSTRUCTIONS PRIOR TO INSTALLATION, INITIAL FIRING, AND BEFORE PERFORMING
ANY SERVICE OR MAINTENANCE. THESE INSTRUCTIONS MUST BE LEFT WITH THE USER AND SHOULD BE
RETAINED FOR FUTURE REFERENCE BY QUALIFIED SERVICE PERSONNEL.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the StyleCrest Revolv VMA3-50D36N and is the answer not in the manual?

Summary

Safety Information

Operating Instructions

Step-by-step guide for safe furnace operation and potential gas leak procedures.

Homeowner Safety Guidelines

Key responsibilities and safety precautions for homeowners regarding furnace maintenance and operation.

Gas Leak Safety Procedures

Immediate actions to take if a gas leak is detected, emphasizing safety and contact procedures.

Handling Flammable Liquids and Compartment Safety

Warning against flammable liquids and ensuring the compartment is closed during operation.

Furnace Specifications

Model Specifications (VMA3 & VMC1 Series)

Detailed technical specifications for VMA3 and VMC1 furnace models, including input, output, and orifices.

Installation Parts Packages

Lists specific parts included in installation packages for different furnace models.

Blower Performance Data

Information on blower motor specifications and performance data for various speeds.

General Instructions and Clearances

Installation Guidelines and Codes

Covers BTU capacity, gas conversion, temperature rise, and compliance with codes.

Clearances to Combustible Materials

Specifies required clearances for closet and alcove installations based on material type.

General Installation

Furnace Location and Base Installation

Guidelines for selecting furnace location and installing bases for VMA3 models.

Alcove and Closet Installation Requirements

Specifies minimum clearances for alcove and closet installations, including return air openings.

Fuel Piping Installation

Procedures and safety warnings for sizing and installing fuel gas piping.

Venting System Requirements and Installation

Rules for installing the vent and air intake system, including pipe size and terminations.

Condensate Drain Line Assembly

Details on connecting the condensate drain trap and optional neutralizer or pump.

Starting the Unit

Sequence of Operations

Flowchart detailing the step-by-step process of furnace ignition and operation.

Initial Startup Procedures

Pre-start checks and operating instructions for initial furnace startup.

BTU Input Rate and Burner Adjustment

Procedures for checking and adjusting BTU input rate and burner flame characteristics.

Setting Temperature Rise and Checkout

How to set temperature rise and perform a furnace checkout after installation.

Installers Instructions to User

Homeowner Information Delivery

Installer's responsibility to inform the homeowner about manual location, controls, and operation.

Dealer Maintenance

Electrical and Vent System Inspection

Checks for wiring integrity, voltage, amp-draw, and vent pipe condition.

Internal Component Inspection

Inspecting condensate line, burners, inducer blower, gaskets, and heat exchanger.

Blower and Filter Maintenance

Cleaning coil air side, house air blower, and servicing the return air filter.

Troubleshooting

Diagnostic Features and LED Codes

Explains the integrated ignition control and LED flashing codes for diagnosing failures.

Troubleshooting Guide Flowchart

A step-by-step diagnostic flowchart to help identify and resolve furnace malfunctions.

System Lockout and Error Conditions

Describes conditions that lead to system lockout and how to reset or resolve them.

StyleCrest Revolv VMA3-50D36N Specifications

General IconGeneral
Model NumberVMA3-50D36N
CategoryFurnace
ManufacturerStyleCrest
SeriesRevolv
Frequency60 Hz
BTU50, 000 BTU