Operation Guidance
Eyepiece
Adjust the eyepiece knob to focus on the target.
Power ON/OFF
1. Press the“ ” to power ON.
2. Automatically switch off after 8s of inactivity.
LCD display
1.Press the LCD display switch to turn ON/OFF the screen.
2.LCD display will switch off automatically after 8s of inactivity.
Angle Calibration
This device is already calibrated before dispatch. If it gives wrong measuring result, the
device should be re-calibrated manually.
1.Power off the device. Press and hold the power button for 5s to enter into Calibration
Interface. “ANGLE CAL” would be shown on screen.
2.Keep the product still for several seconds to complete the calibration. If the calibration
is not completed in a long time, the device will turn off automatically in a minute
3.If the calibration is not completed, the product would restore to factory setting when it
is restarted.