700-2 SERIES (Base Units)
Troubleshooting Input Operations
» Diagnostic Mode
1. Unit must be ON
2. Press COLDER & UNIT ON/OFF keys simultaneously, then
release both keys
NOTE: After performing the above key strokes, the following will
appear on the LCD. Temperatures shown are for reference only,
actual temperatures may vary.
If Model 700BF:
0000
SERVICE (Illuminated)
FF
Temperature of F (Freezer Compartment)
- Press COLDER key to toggle to next reading
--1100
SERVICE (Illuminated)
EE
Temperature of E (Freezer Evaporator)
If Model 700BR:
3366
SERVICE (Illuminated)
LL
Temperature of L (Lower Compartment)
3366
SERVICE (Illuminated)
UU
Temperature of U (Upper Compartment)
2299
SERVICE (Illuminated)
EE
Temperature of E (Refrigerator Evaporator)