22
|
Sub-Zero Customer Care 800.222.7820
Electrical
Installation must comply with all applicable electrical codes.
The electrical supply should be located within the shaded
area shown in the illustration below. A separate circuit, ser-
vicing only this appliance is required. A ground fault circuit
interrupter (GFCI) is not recommended and may cause inter-
ruption of operation.
ELECTRICAL REQUIREMENTS
Power Supply 115 V AC, 60 Hz
Circuit Breaker 15 amp
Receptacle 3-prong grounding-type
CAUTION
The outlet must be checked by a qualied electrician to
be sure that it is wired with the correct polarity. Verify
that the outlet is properly grounded.
WARNING
Do not use an extension cord, two-prong adapter or
remove the power cord ground prong.
FRONT VIEW
75
1
/2"
(1918)
FROM
FLOOR
7"
(178)
E
6"
(152)
Electrical supply location.
Dual Installation
If two units are installed side by side, a dual installation kit
may be required. Installations without a custom ller strip
require a dual installation kit. If a dual installation kit is not
specied, a 2"
(51) ller strip is recommended between units.
Dual installations without a ller strip can only be accom-
plished using two units with opposite hinges. Refer to the
illustrations below.
Dual installation kits are available through an authorized
Sub-Zero dealer. For local dealer information, visit the nd a
showroom section of our website, subzero.com. For ques-
tions regarding the installation, call Sub-Zero customer care
at 800-222-7820.
WITHOUT FILLER STRIP
FILLER STRIP
Opposite hinges.
Same side hinges.
MODEL WS-30 SITE PREPARATION