Model WS-30 Installation 36
Electrical Requirements
F
or model WS-30, the electrical supply should be located
within the shaded area shown in the illustration. Follow the
National Electrical Code and local codes and ordinances
when installing the receptacle. A separate circuit, servicing
only this appliance is required. A ground fault circuit inter-
rupter (GFCI) is not recommended and may cause inter-
ruption of operation.
Electrical Requirements
Power Supply 115 V AC, 60 Hz
Circuit Breaker 15 amp
Receptacle 3-prong grounding-type
FRONT VIEW
75
1
/2"
(1918)
FROM
FLOOR
7"
(178)
E
6"
(152)
Location of electrical supply.
Do not use an extension cord or two-prong adapter.
Electrical ground is required on this appliance. Do not
remove the power cord ground prong.
The outlet must be checked by a qualified electrician to
be sure that it is wired with the correct polarity and is
properly grounded.