Manual Entry Model Configuration Mode
Manual Entry Model Configuration Mode allows a Service Technician to verify a main control board of the 427R
refrigerator section was configured correctly, and/or to reconfigure the main control board if a mistake was made
during the configuration process.
To initiate Manual Entry Model Configuration Mode the unit must be ON and the bottom drawer open
. Then, Press
and hold the drawer ajar alarm bell ON/OFF key and the UNIT ON/OFF key together for 15 seconds. The unit will
now be in Model Configuration Mode, with the model code of the last configuration displayed (See Figure 3-89 and
Model Code Table on previous page). If needed, toggle through the model codes by pressing WARMER or COLD-
ER keys, until appropriate model code is displayed (See Figure 3-90 and 3-91). With appropriate model code dis-
played, press UNIT ON/OFF key to store model configuration (See Figure 3-92).
Figure 3-89. Press Alarm and UNIT ON/OFF key to Initiate Manual Entry Model Configuration Mode