Dimensions in parentheses are in
millimeters unless otherwise specified.
In areas with water of high mineral content,
the use of an in-line water filter is recom-
m
ended. Make sure the filter is positioned and
accessible for replacement when necessary.
IMPORTANT NOTE:
The ice maker will not
fill with water immediately. Allow 24 hours for
p
roper ice production. Let your customer know
that the first container filled with ice should be
discarded, as with any new connection there
may be impurities in the ice from the water
supply line.
WATER LINE CONNECTION
QUICK CONNECT WATER VALVE
For units with an ice maker, the quick connect
water valve and PEX tubing are located on the
r
ight-hand side of the unit towards the bottom.
Follow these instructions to connect the ice
maker water line.
Attach the union fitting to the copper house
water supply line. Pull the coiled gray PEX
tubing with a red cap and captured metal nut
toward the house water supply line. Remove
and discard the red cap, then attach the tubing
to the union with captured nut. Tighten all
connections. Recoil the excess tubing under
the unit. Refer to illustration 10 below.
IMPORTANT NOTE:
Turn on the water supply
and check all fittings for leaks. Make certain
the electrical harness is attached to the
solenoid.
INTEGRATED INSTALLATION INSTRUCTIONS
PEX
Tubing
Illus. 10
Shut power off at the circuit breaker
before making electrical connection to
the solenoid, if required.