PRO 48 Site Preparation 6
Electrical Requirements
Power Supply 115 V AC, 60 Hz
Circuit Breaker 15 amp
Receptacle 3-prong grounding-type
Do not use an extension cord or two-prong adapter.
Do not remove the power supply cord ground prong.
The outlet must be checked by a qualified electrician to
be sure that it is wired with the correct polarity. Verify
that the outlet is properly grounded.
FRONT VIEW
75
1
/2"
(1918)
FROM
FLOOR
7"
(178)
E
6"
(152)
Location of electrical supply.
Electrical Requirements
F
or PRO 48 models, the electrical supply should be
located within the shaded area shown in the illustration
below. Follow the National Electrical Code and local codes
and ordinances when installing the receptacle. A separate
circuit, servicing only this appliance is required. A ground
fault circuit interrupter (GFCI) is not recommended and
may cause interruption of operation.
Always shut power off at the circuit breaker before
performing any installation, service or maintenance.