PRO 48 Installation 8
IMPORTANT NOTE: F
or either wood or concrete floor
applications, if the wood screws do not hit a wall stud in
any of the upper holes on the anti-tip bracket, use the
provided #8–18 x 1
1
/4" wood screw, #12 flat washer and
nylon zip-it wall anchor in its place.
IMPORTANT NOTE: In some installations the subflooring
or finished floor may necessitate angling the screws used
to fasten the anti-tip bracket to the back wall.
Anti-Tip Bracket Installation
IMPORTANT NOTE: Placement of the anti-tip bracket is
critical to a stable installation. Failure to properly position
the anti-tip bracket will prevent it from engaging the unit.
The anti-tip bracket must be installed exactly 26"
(660)
from the front of the face frame of the unit to the back of
the anti-tip bracket. Also, the centering line on the lower
flange of the anti-tip bracket must be centered in the
rough opening. Make sure the anti-tip bracket is installed
on a solid base. Refer to the illustration below.
To properly secure the anti-tip bracket for a stable installa-
tion, use all anti-tip bracket hardware as instructed for
wood or concrete floors.
To prevent the PRO 48 from tipping forward and
provide a stable installation, the unit must be secured
in place with the anti-tip bracket provided with the unit.
Make sure there are no electrical wires or plumbing in
the area which the screws could penetrate.
Anti-tip bracket.
Anti-Tip Bracket Hardware
1 Anti-tip bracket
12 #12 x 2
1
/2" PN HD wood screws
3
3
/8" x 3
3
/4" Trubolt anchors
12 #12 flat washers
3 #8–18 x 1
1
/4" AB PH HD screws
3 Nylon zip-it wall anchors