EasyManuals Logo

Suburban SF-20F Service Manual

Default Icon
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
3
circulate room air across the furnace chamber where it is heated. The blower then forces the hot air into the living area either
through a duct system or through a front grille on the furnace cabinet on direct discharge models.
Suburban furnaces operate on 12-volt DC power which is supplied either by a 12-volt battery or a converter system. A
recreational vehicle furnace that is specifically designed for “park model” trailers operates on 120 volts AC. These are designed
and tested under the same standards as the 12-volt models.
Suburban forced draft combustion furnaces used in recreational vehicles are designed for use with Propane gas. Although a few
recreational vehicle furnaces are approved for use with natural gas, one should never attempt to convert such a unit to natural
gas unless the conversion is approved by the manufacturer of the furnace.
Gas Supply Pressure Requirements
Line Pressure:
Minimum 11" WC*, Maximum 14" WC
*WC - water column
Voltage Requirements
Voltage DC: 12 volt D.C.
Minimum 10.5 volts D.C., Maximum 13.5 volts D.C.
Service Tools Required
Manometer gauge/ U-Tube
Volt ohm meter capable of testing above 15 amps
Module board tester #641511
Gas leak detector OR approved leak check liquid
Assorted wrenches
Assorted hand tools
Safety glasses
Suburban
RV FURNACES
12 VDC Direct
BTU/h
Shipping
Discharge
Input
Height
Width
Depth
Ignition
Weight
NT-12SE
12,000
9 3/8"
9 3/8"
21-27 3/4"
Electronic
27
NT-16SE
16,000
9 3/8"
9 3/8"
21-27 3/4"
Electronic
27
NT-20SE
19,000
9 3/8"
9 3/8"
21-27 3/4"
Electronic
27
DD-17DSI
17,000
12"
10 1/2"
22-29"
Electronic
25
Accessories
Description
260197
Vent Kit 2" - 4" DD Models
260198
Vent Kit 4" - 6" DD Models
260199
Vent Kit 6" - 9" DD Models
12 VDC Ducted
BTU/h
Shipping
Furnaces
Input
Height
Width
Depth
Ignition
Weight
NT-12S
12,000
9 3/8"
9 3/8"
22 3/4-29 1/2"
Electronic
27
NT-16S
16,000
9 3/8"
9 3/8"
22 3/4-29 1/2"
Electronic
27
NT-20S
19,000
9 3/8"
9 3/8"
23 3/8-30 1/8"
Electronic
27