INTRODUCTION – INTENDED USE
The product is artistically made and it is installed to allow a constant air exchange inside the
room. The recovery system can be generally installed in residential or public places.
The product is supplied with a ceramic heat exchanger that accumulates heat during the
extraction of hot air coming from the room while, during the air intake from the outside, the
device transfers to the inlet cold air, the thermal energy stored in the heat exchanger.
The product is designed for wall installation. The duct containing the heat exchanger is sup-
plied for walls with a maximum thickness of 500mm; the duct can be shorten to a minimum
of 250mm.
The extracted or incoming air must not contain inflammable or explosive mixtures, chemical
vapors, dusts, oils and other pathogenic substances in general.
INTRODUCTION – PRODUCT OVERVIEW
The product is composed of a main unit with front tilting panel to be placed inside the room,
a recessed duct that contains the ceramic heat exchanger and filters and an external
soundproof grille.
5- Main unit
6- Front tilting panel
7- Heat exchanger
8- Filters
6- 500mm recessed duct
7- External grille
8- Caps for recessed duct